Understanding Pipe Dimensions in Theatre Rigging Systems: Compliance with ASTM, ANSI, NFPA, and Other Pertinent Standards

In theatre environments, overhead pipe systems—commonly referred to as battens—play a critical role in suspending scenery, lighting, drapery, and other production elements. These systems must be structurally reliable and safe, especially when flown or counterweighted. Rigorous compliance with recognized standards is essential to prevent failure, ensure performer and technician safety, and maintain regulatory alignment with building codes and industry guidelines.

This article outlines the common dimensions of theatrical pipe systems, discusses their application, and details the standards and codes that govern their use in entertainment venues.

Typical Pipe Dimensions Used in Theatre

The most common pipe used in theatrical rigging systems is Schedule 40 steel pipe, specifically 1.5-inch nominal diameter (NPS 1½), which has an outside diameter (OD) of 1.9 inches and a wall thickness of 0.145 inches. This standard pipe size is widely used because it offers a good balance of strength and weight for supporting theatrical loads such as soft goods and lighting instruments.

Other Pipe Sizes Occasionally Used:

  • NPS 1¼” Schedule 40 (1.66″ OD): Sometimes used for lighter-duty battens.
  • NPS 2″ Schedule 40 (2.375″ OD): Rarely used in traditional battens, but occasionally for structural applications or curved pipes or specifically engineered applications.

Smaller theaters, especially in K-12 schools, may have battens with a thinner wall thickness. When present, signage must be posted that lists the load ratings. Conduit and wood should never be used, but may be found in some theaters.

Splicing and Support Considerations

Battens often span 30–60 feet and may be spliced from multiple lengths of pipe using sleeves or couplers. Splices must maintain alignment, structural integrity, and load capacity. Horizontal spacing between support points (loft blocks or lift lines) should prevent excessive deflection, typically targeting less than 1/360 of the span, which aligns with industry best practices (ESTA, 2020).

Common Applicable Standards and Codes (Not an exhaustive list)

1. ASTM Standards

  • ASTM A53 / A53M-20: Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless. This standard governs the physical and chemical properties of steel pipe used in rigging systems (ASTM, 2020).
  • ASTM A500 / A500M-21: Covers cold-formed welded and seamless carbon steel structural tubing, occasionally used for curved battens or structural pipe grids.

2. ANSI Standards (ESTA Technical Standards Program)

  • ANSI E1.4-1 – 2016: Entertainment Technology—Manual Counterweight Rigging Systems. This standard outlines acceptable practices for the installation and inspection of battens, lift lines, and supporting hardware (ESTA, 2016).
  • ANSI E1.43 – 2021: Performer Flying Systems. When pipe battens are used in systems supporting performers, this standard applies.
  • ANSI E1.50-1 – 2016: Guidelines for the Measurement and Specification of Theatrical Luminaires. While focused on lighting, this standard indirectly affects pipe loading and spacing.

3. NFPA Standards

  • NFPA 80 – 2022: Fire Doors and Other Opening Protectives. Relevant when pipes support fire-rated curtains.
  • NFPA 101 – 2021: Life Safety Code. Addresses egress and occupancy hazards associated with suspended equipment.
  • NFPA 70 (NEC) – 2023: National Electrical Code. Governs proximity of electrical equipment to metal battens and grounding requirements.

4. OSHA & Building Codes

  • OSHA 1910 Subpart D: Walking-Working Surfaces. Applies if the pipe system forms part of an accessible overhead structure or grid.
  • International Building Code (IBC): Requires structural systems, including theatrical rigging, to be designed per ASCE 7. Engineers must verify pipe battens are designed to withstand loading with appropriate safety factors (ICC, 2021).

Design Factors and Load Ratings

Design professionals should consider:

  • Span between supports
  • Total uniform and point loads (e.g., lighting clamps, scenery)
  • Load rating per linear foot: A standard 1.5″ Schedule 40 pipe has a working load limit of approximately 125–200 lbs per foot, depending on span and deflection tolerances.
  • Deflection: Excessive sag may affect aesthetics and safety. A deflection limit of L/360 is standard for theatrical battens.

The load capacity of the pipe should always be derated for splices, clamp locations, and any eccentric loading. In cases where battens are motorized or part of a dead-hung grid, additional mechanical and structural standards apply.

Recommendations for Compliance

  1. Use only ASTM A53 Schedule 40 pipe from a reputable manufacturer.
  2. Avoid using aluminum pipe unless engineered for specific lightweight loads—aluminum has different failure modes and lacks the ductility of steel.
  3. Do not drill through the pipe wall—this compromises structural integrity. Use proper pipe clamps approved for theatrical use.
  4. Label pipe battens clearly at dead ends and splices to assist with inspection and maintenance.
  5. Maintain documentation for each system’s load capacity and inspection history.
  6. Have a qualified ETCP-certified Theater rigger or engineer inspect pipe systems annually and after any significant change in loading or configuration.

Theatrical pipe systems are deceptively simple but require careful attention to engineering, material specifications, and regulatory compliance. From ASTM steel specifications to ANSI safety guidelines and NFPA code adherence, every element plays a role in ensuring a safe working and performing environment.

References

American Society for Testing and Materials. (2020). ASTM A53/A53M-20: Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless. https://www.astm.org/a0053_a0053m-20.html

American Society for Testing and Materials. (2021). ASTM A500/A500M-21: Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing. https://www.astm.org/a0500_a0500m-21.html

ESTA. (2016). ANSI E1.4-1 – 2016: Manual Counterweight Rigging Systems. Entertainment Services and Technology Association. https://tsp.esta.org/

ESTA. (2021). ANSI E1.43 – 2021: Performer Flying Systems. Entertainment Services and Technology Association. https://tsp.esta.org/

International Code Council. (2021). International Building Code (IBC). https://codes.iccsafe.org

National Fire Protection Association. (2023). NFPA 70: National Electrical Code. https://www.nfpa.org/

National Fire Protection Association. (2021). NFPA 101: Life Safety Code. https://www.nfpa.org/